Factories and business sites
Commercial & Industrial Solutions
Battery cabinets that cut peak demand charges, keep operations running through outages and reduce diesel generator costs.
Factories and business sites
Battery cabinets that cut peak demand charges, keep operations running through outages and reduce diesel generator costs.
Cabinet systems
Each cabinet combines PCS and lithium-ion battery technology in one integrated platform, air-cooled or immersion-cooled. The platform supports peak shaving, microgrids and diesel hybrid operation that reduces fuel and maintenance costs. Performance stays stable in desert, high-altitude and coastal conditions.
Energy per cabinet, modular
Rated power
At 100% DOD to 80% SOH
Operating range, derating above 45 °C
Use cases
Cut the site peak to cap demand charges.
Move consumption to low-tariff hours.
Ride through outages without stopping production.
Stabilize heavy, cyclic and motor-starting loads.
Replace or hybridize generators to cut fuel, logistics, maintenance, noise and exhaust fumes.
Buffer high-power charging without a grid upgrade.
Flexible by design
We tailor capacity, cooling and enclosure around our core products to fit each site.
Air-cooled
HVAC thermal management for standard C&I sites.
Immersion-cooled
Cells are immersed in coolant for the highest safety and heat tolerance.
Final configuration, capacity and degradation over life are confirmed in the technical proposal for each project.
| Specification | Value |
|---|---|
| Energy capacity | 241–522 kWh per cabinet, modular |
| Rated power | 125–250 kW |
| Battery chemistry | LFP |
| Cooling | Air-cooled (HVAC) or immersion-cooled |
| Cycle life | ≥ 6,000 cycles (0.5P, 25 ± 2 °C, 100% DOD, 80% SOH) |
| Format | Outdoor or indoor cabinets |
| Operating temperature | −20 °C to +55 °C (derating above 45 °C) |
| Operating altitude | 4,000 m (derating above 2,000 m) |
| Protection rating | IP54 |
| Fire suppression | Aerosol |
| Communication | RS485, LAN |
Redundant safety measures at every level: prevent, detect, contain and verify. Engineered from the battery cell outward.
A defined sequence with a named deliverable at every step: questionnaire, technical proposal and SLD, FAT report, SAT report and as-built pack.